UMMS Affiliation

Imaging and Radiation Oncology Core QA Center Rhode Island; Department of Radiation Oncology

Publication Date

2019-01-06

Document Type

Article

Disciplines

Neoplasms | Oncology | Radiation Medicine | Radiology | Translational Medical Research

Abstract

Introduction: Target delineation variability is a significant technical impediment in multi-institutional trials which employ intensity modulated radiotherapy (IMRT), as there is a real potential for clinically meaningful variances that can impact the outcomes in clinical trials. The goal of this study is to determine the variability of target delineation among participants from different institutions as part of Southwest Oncology Group (SWOG) Radiotherapy Committee's multi-institutional in-silico quality assurance study in patients with Pancoast tumors as a "dry run" for trial implementation.

Methods: CT simulation scans were acquired from four patients with Pancoast tumor. Two patients had simulation 4D-CT and FDG-FDG PET-CT while two patients had 3D-CT and FDG-FDG PET-CT. Seventeen SWOG-affiliated physicians independently delineated target volumes defined as gross primary and nodal tumor volumes (GTV_P and GTV_N), clinical target volume (CTV), and planning target volume (PTV).Six board-certified thoracic radiation oncologists were designated as the 'Experts' for this study. Their delineations were used to create a simultaneous truth and performance level estimation (STAPLE) contours using ADMIRE software (Elekta AB, Sweden 2017). Individual participants' contours were then compared with Experts' STAPLE contours.

Results: When compared to the Experts' STAPLE, GTV_P had the best agreement among all participants, while GTV_N showed the lowest agreement among all participants. There were no statistically significant differences in all studied parameters for all TVs for cases with 4D-CT versus cases with 3D-CT simulation scans.

Conclusions: High degree of inter-observer variation was noted for all target volume except for GTV_P, unveiling potentials for protocol modification for subsequent clinically meaningful improvement in target definition. Various similarity indices exist that can be used to guide multi-institutional radiotherapy delineation QA credentialing.

Keywords

Contouring, Pancoast tumor, QA, Quality assurance, Target volumes, Thoracic

Rights and Permissions

Copyright 2019 The Authors. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

DOI of Published Version

10.1016/j.ctro.2019.01.001

Source

Clin Transl Radiat Oncol. 2019 Jan 6;15:83-92. doi: 10.1016/j.ctro.2019.01.001. eCollection 2019 Feb. Link to article on publisher's site

Journal/Book/Conference Title

Clinical and translational radiation oncology

Comments

Full author list omitted for brevity. For the full list of authors, see article.

Related Resources

Link to Article in PubMed

PubMed ID

30775563

Creative Commons License

Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License
This work is licensed under a Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License.