Title

Circulating monocyte-platelet aggregates are an early marker of acute myocardial infarction

UMMS Affiliation

Department of Medicine, Division of Cardiovascular Medicine; Center for Platelet Function Studies

Publication Date

10-5-2001

Document Type

Article

Subjects

Creatine Kinase; Creatine Kinase, MB Form; Female; Flow Cytometry; Humans; Isoenzymes; Male; Middle Aged; Monocytes; Myocardial Infarction; P-Selectin; Platelet Activation; Platelet Aggregation

Disciplines

Bioinformatics | Biostatistics | Epidemiology | Health Services Research

Abstract

OBJECTIVES: We investigated whether elevated levels of circulating monocyte-platelet aggregates (MPA) can be used to identify patients with acute myocardial infarction (AMI).

BACKGROUND: Commonly used blood markers of AMI reflect myocardial cell death, but do not reflect the earlier pathophysiologic processes of plaque rupture, platelet activation and resultant thrombus formation. Circulating MPA form after platelet activation. METHODS: In a single center between October 1998 and November 1999, we measured circulating MPA in a blinded fashion by whole blood flow cytometry in 211 consecutive patients who presented to the emergency department (ED) with chest pain and were admitted to rule out AMI. Acute myocardial infarction was diagnosed by a CK-MB fraction greater than three times control.

RESULTS: Patients with AMI (n = 61), as compared with those without AMI (n = 150), had significantly higher numbers of circulating MPA (11.6 +/- 11.4 vs. 6.4 +/- 3.6, mean +/- SD, p < 0.0001). After controlling for age, the adjusted odds of developing AMI for patients in the 2nd, 3rd and 4th quartiles of MPA, in comparison with patients in the lowest quartile (odds ratio = 1.0), were 2.1 (95% confidence interval [CI]: 0.7, 6.8), 4.4 (95% CI: 1.5, 13.1) and 10.8 (95% CI: 3.6, 32.0), respectively. The number of circulating MPA in patients with AMI presenting within 4 h of symptom onset (14.4) was significantly greater than those presenting after 4 h (9.4) and after 8 h (7.0), (p < 0.001). Of the 61 patients with AMI, 35 (57%) had a normal creatine kinase isoenzyme ratio at the time of presentation to the ED, but had high levels of circulating MPA (13.3).

CONCLUSIONS: Circulating MPA are an early marker of AMI.

Rights and Permissions

Citation: J Am Coll Cardiol. 2001 Oct;38(4):1002-6.

Journal/Book/Conference Title

Journal of the American College of Cardiology

PubMed ID

11583872

Related Resources

Link to Article in PubMed